Technical#1: LBP, MBP and HBP: Meaning and application overview.

In a small series of short articles, we look at technical facets of refrigeration. Part 1 is about compressor application areas. In the further course of the series, we will look at other aspects to consider when selecting replacement compressors.

Compressors are divided into 4 types according to application: LBP, MBP, HBP and AC. In this blog post we will give a brief overview of the application areas and the meaning of these terms.

LBP

LBP means "Low Back Pressure" - these compressors are used when low evaporating temperatures are required. LBP compressors are used for example in deep freezers, freezers and preservers.

MBP

The abbreviation MBP means "Medium Back Pressure" - accordingly, these compressors are used in the range of medium evaporating temperatures. Examples of applications are beverage coolers or sales counters.

HBP

Not surprisingly, "HBP" stands for "High Back Pressure" and HBP compressors are used in the field of high evaporation temperatures. You will find HBP compressors for example in dehumidifiers or construction dryers.

AC

AC stands for "Air Conditioning" - AC compressors are used in the air conditioning sector.

It is worth noting that this nomenclature is not uniformly standardized and the application limits can change depending on the compressor manufacturer. It is also very common to couple 2 applications if the compressor can be used for both applications, for example L/MBP.

The application range of a compressor should definitely be considered when selecting a replacement compressor. If, for example, an HBP compressor is replaced with an LBP compressor, functional failures will occur - since the latter was designed accordingly for completely different application areas and evaporating temperatures.

If you need assistance in selecting a replacement compressor, please feel free to contact us.

In addition to the area of application, the refrigerant is also a factor that must be taken into account when selecting a replacement compressor. Since different refrigerants have different working pressures, serious functional problems can occur if a compressor is filled with the wrong refrigerant. We will go into the background here in a later blog post.

Comments (8)

Ed

November 29, 2022 02:33

Clear and precise

Jóse Antonio Vázquez Cano

June 2, 2023 18:42

Tengo un compresor el cual no tiene dispositivo de ARRANQUE EL compresor cuento con una etiqueta Amarilla (SC12MLX ) , 220 230V 60Hz,MBP,HST,R404/R507 Quisiera Saber la capacidad del sismo y los números de Relevador, térmico y los microfaradios y voltaje del capacitor Que atento Asus comentarios Gracias.

Helio Brasil Martins

September 29, 2023 15:43

Para máquina comercial de hielo en cubitos que compresor es el indicado el de media o el de alta?

Ray

January 2, 2024 01:17

can you please tell me on the pressures what does each work with in the system capillary tube and expansion valve low back pressure--IBP--- is used with expansion valve or capillary tube GENERALLY HBP --------- EXPANSION OR CAP THANK YOU

Rolando Pérez

March 14, 2024 17:06

Pregunto se puede sustituir un compresor de un refrigerador Mabe que trae instalado originalmente un compresor de 220 v de 1/6 HP por un compresor de 110v de 1/5 HP.Por supuesto cambiando los demás elementos por componentes que se alimenten de 110 v.

Luis jose girotti

May 27, 2024 04:06

Buenos dias, quisiera saber que es lo que identifica o diferencia los compresores de heladeras es decir los de alta presion retorno baja y media, si tien que ver con su potencia tamaño capacidad espero su contestacion . Gracias.

Gilberto Espinosa

June 1, 2024 13:38

Necesito reemplazar un compresor el modelo ffu160uax r290a cuál es el reemplazo que le debe quedar

Olber Sarmiento

July 12, 2024 14:45

Tengo un problema con mi refrigerador DAEWOO, se me quemó la máquina tipo LU66XZ1 original de 1/5, compré otr NF5.5FX Danfos de 1/5, pero no he logrado el enfriamiento original del equipo