Skip to main content Skip to search Skip to main navigation
Menu

Sight glass Carly VCYL 52 MMS Solder connection 6 mm

37-VCYL52MMS
Contact
Privacy
Fields marked with asterisks (*) are required.
Description
Sight glass Carly VCYL 52 MMS Solder connection 6 mm

Functional features:
- Maximum operating pressure: 42 bar
- Compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives
- The glass size enables excellent visibility without being impaired by a central hygroscopic bead.
- The mounting design of the humidity indicator is such that it is not subject to wear, contamination by oils or residual substances in the refrigerant circuit. It prevents turbulence that could have an unfavourable effect on the good visibility of the refrigerant and does not cause a drop in pressure.
- The monobloc design and the perfectly fitted inspection window guarantee absolute tightness.
- The two flare connections are provided with a hexagonal spanner flat for easy installation and screwing in.
- The male / female sight glasses for flanging are supplied with a centring copper gasket on the female side (except VCYL 25, where a non-centring copper gasket is included), which enables quick and secure positioning.
- The male / female sight glasses can be screwed directly onto the outlet side of a filter drier.
- Due to the low weight of the VCYL sight glasses, no special fastening is required.
- The base body of the sight glasses is made of brass, guaranteeing complete corrosion resistance.
- Several types of connections are possible on the standard products:
- Screw connection type SAE, Male/Male and Male/Female
- For soldering on tubes in millimetre (MMS), Female/Female and Male/Female

Application:
- For quick and direct control of flow, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems.

For more information, see the data sheet above.
Downloads

Data and Illustrations without Guarantee

Manufacturer "Carly"

CARLY

CARLY is a French manufacturer of components for refrigeration and air conditioning systems, headquartered in Lissieu, France. Since its foundation in 1923, the company has specialised in the development and production of solutions for refrigeration and air conditioning technology. CARLY operates internationally and offers a wide range of products for various applications in refrigeration and air conditioning technology.

Product groups and specialisations:

CARLY offers a comprehensive range of products for refrigeration and air conditioning technology:

  • Filtration, drying and decontamination: products for the filtration and drying of refrigerants, as well as for the decontamination of systems.
  • Service products: Maintenance products such as cleaning and disinfecting agents for refrigeration and air-conditioning systems.
  • Refrigeration fittings: Connectors for refrigerant circuits.
  • Noise and vibration damping: Products for reducing noise and vibrations in systems.
  • Tanks, liquid separators and coil condensers: Components for the storage and transport of refrigerants.
  • Refrigeration valves: Valves for regulating the flow of refrigerant.
  • Oil control systems: Systems for monitoring and managing oil flow in refrigeration systems.

This wide range of products underscores CARLY’s commitment to quality and innovation in refrigeration and air conditioning technology.

 

Manufacturer details (information requirements under the GPSR Product Safety Regulation):

Manufacturer: CARLY GmbH

Postal address: Steigerstraße 5 67811 Dielkirchen Germany

Email address: [email protected]

Website: www.carly-sa.de

Properties
Connection: Connection
Connection size: Connection Size
Item condition: New item

Data and Illustrations without Guarantee

Downloads

Do you have some questions about this product?

Skip product gallery

Artikel Zubehör

Sight glass Carly VCYL 36 MMS Solder connection 18 mm
Sight glass Carly VCYL 36 MMS Solder connection 18 mm
Sight glass Carly VCYL 36 MMS Solder connection 18 mmFunctional features: - Maximum operating pressure: 42 bar - Compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives - The glass size allows excellent visibility without a central hygroscopic bead impairing this.- The mounting design of the humidity indicator is such that it is not subject to wear, contamination by oils or residual substances in the refrigerant circuit. It prevents turbulence that could have an unfavourable effect on the good visibility of the refrigerant and does not cause a drop in pressure. - The monobloc design and the perfectly fitted inspection window guarantee absolute tightness. - The two flare connections are provided with a hexagonal spanner flat for easy installation and screwing in. - The male / female sight glasses for flanging are supplied with a centring copper gasket on the female side (except VCYL 25, where a non-centring copper gasket is included), which enables quick and secure positioning. - The male / female sight glasses can be screwed directly onto the outlet side of a filter drier. - Due to the low weight of the VCYL sight glasses, no special fastening is required. - The base body of the sight glasses is made of brass, guaranteeing complete corrosion resistance. - Several types of connections are possible on the standard products: - Screw connection type SAE, Male/Male and Male/Female - For soldering on tubes in millimetre (MMS), Female/Female and Male/Female Application: - For quick and direct control of flow, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems. For more information, see the data sheet above.
  • Available
  • Delivery Time : 2-5 business days
Regular price: €71.28
Sight glass Carly VCYL 37 S/MMS Solder connection 7/8"' - 22 mm
Sight glass Carly VCYL 37 S/MMS Solder connection 7/8"' - 22 mm
Sight glass Carly VCYL 37 S/MMS Solder connection 7/8"' - 22 mmFunctional features: - Maximum operating pressure: 42 bar - Compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives - The glass size enables excellent visibility without being impaired by a central hygroscopic bead.- The mounting design of the humidity indicator is such that it is not subject to wear, contamination by oils or residual substances in the refrigerant circuit. It prevents turbulence that could have an unfavourable effect on the good visibility of the refrigerant and does not cause a drop in pressure. - The monobloc design and the perfectly fitted inspection window guarantee absolute tightness. - The two flare connections are provided with a hexagonal spanner flat for easy installation and screwing in. - The male / female sight glasses for flanging are supplied with a centring copper gasket on the female side (except VCYL 25, where a non-centring copper gasket is included), which enables quick and secure positioning. - The male / female sight glasses can be screwed directly onto the outlet side of a filter drier. - Due to the low weight of the VCYL sight glasses, no special fastening is required. - The base body of the sight glasses is made of brass, guaranteeing complete corrosion resistance. - Several types of connections are possible on the standard products: - Screw connection type SAE, Male/Male and Male/Female - For soldering on tubes in millimetre (MMS), Female/Female and Male/Female Application: - For quick and direct control of flow, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems. For more information, see the data sheet above.
  • Available
  • Delivery Time : 2-5 business days
Regular price: €77.23
Sight glass Carly VCYL 39 MMS solder connection 28 mm
Sight glass Carly VCYL 39 MMS solder connection 28 mm
Sight glass Carly VCYL 39 MMS Solder connection 28 mmFunctional features: - Maximum operating pressure: 42 bar - Compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives - The glass size enables excellent visibility without being impaired by a central hygroscopic bead.- The mounting design of the humidity indicator is such that it is not subject to wear, contamination by oils or residual substances in the refrigerant circuit. It prevents turbulence that could have an unfavourable effect on the good visibility of the refrigerant and does not cause a drop in pressure. - The monobloc design and the perfectly fitted inspection window guarantee absolute tightness. - The two flare connections are provided with a hexagonal spanner flat for easy installation and screwing in. - The male / female sight glasses for flanging are supplied with a centring copper gasket on the female side (except VCYL 25, where a non-centring copper gasket is included), which enables quick and secure positioning. - The male / female sight glasses can be screwed directly onto the outlet side of a filter drier. - Due to the low weight of the VCYL sight glasses, no special fastening is required. - The base body of the sight glasses is made of brass, guaranteeing complete corrosion resistance. - Several types of connections are possible on the standard products: - Screw connection type SAE, Male/Male and Male/Female - For soldering on tubes in millimetre (MMS), Female/Female and Male/Female Application: - For quick and direct control of flow, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems. For more information, see the data sheet above.
  • Available
  • Delivery Time : 2-5 business days
Regular price: €83.18