Skip to main content Skip to search Skip to main navigation
Menu

Sight glass Carly VCYL 32 MMS Solder connection 6 mm

37-VCYL32MMS
Contact
Privacy
Fields marked with asterisks (*) are required.
Description

Product description: Sight glass Carly VCYL 32 MMS solder connection 6 mm

Introduction:

The Carly VCYL 32 MMS sight glass is a high-quality product for quickly and directly checking the flow, condition and moisture content of the refrigerant in refrigeration and air conditioning systems. It is perfect for professionals in refrigeration, air conditioning and ventilation technology as well as in the heat pump sector.

Technical features:
  • Maximum operating pressure: 42 bar
  • Compatible with CHCs, CFCs, HFCs, CO2 and their oils and additives
  • Excellent visibility due to glass size without hygroscopic beads
  • Fixed construction prevents wear and pressure drop
  • Monobloc construction for absolute tightness
  • Brass body for corrosion resistance
  • Easy soldering of the connections thanks to long copper soldering ends
  • Various connection types possible: screw connection, soldering on pipes

Sales-promoting contents:

1. the VCYL sight glasses guarantee reliable monitoring of the refrigerant without the need for time-consuming fastening

.

2. the robust design and high-quality materials ensure a long service life and safe use in various systems

3. thanks to the clear view of the sight glass, problems can be recognised and rectified at an early stage, resulting in an efficient and reliable refrigeration and air conditioning system.

Downloads

Data and Illustrations without Guarantee

Manufacturer "Carly"

CARLY

CARLY is a French manufacturer of components for refrigeration and air conditioning systems, headquartered in Lissieu, France. Since its foundation in 1923, the company has specialised in the development and production of solutions for refrigeration and air conditioning technology. CARLY operates internationally and offers a wide range of products for various applications in refrigeration and air conditioning technology.

Product groups and specialisations:

CARLY offers a comprehensive range of products for refrigeration and air conditioning technology:

  • Filtration, drying and decontamination: products for the filtration and drying of refrigerants, as well as for the decontamination of systems.
  • Service products: Maintenance products such as cleaning and disinfecting agents for refrigeration and air-conditioning systems.
  • Refrigeration fittings: Connectors for refrigerant circuits.
  • Noise and vibration damping: Products for reducing noise and vibrations in systems.
  • Tanks, liquid separators and coil condensers: Components for the storage and transport of refrigerants.
  • Refrigeration valves: Valves for regulating the flow of refrigerant.
  • Oil control systems: Systems for monitoring and managing oil flow in refrigeration systems.

This wide range of products underscores CARLY’s commitment to quality and innovation in refrigeration and air conditioning technology.

 

Manufacturer details (information requirements under the GPSR Product Safety Regulation):

Manufacturer: CARLY GmbH

Postal address: Steigerstraße 5 67811 Dielkirchen Germany

Email address: [email protected]

Website: www.carly-sa.de

Properties
Connection: Connection
Connection size: Connection Size
Item condition: New item

Data and Illustrations without Guarantee

Downloads

Do you have some questions about this product?

Skip product gallery

Artikel Zubehör

Sight glass Carly VCYL 12 flared connection 1/4"
Sight glass Carly VCYL 12 flared connection 1/4"
Learn more about the VCYL 12 sight glass for refrigeration and air conditioning systems The VCYL 12 sight glass is an innovative product that has been specially developed for quick and direct monitoring of the flow, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems. It is ideal for installers, service technicians and operators of refrigeration and air conditioning systems who want to ensure efficient monitoring and maintenance of their systems.Technical details: Maximum operating pressure: 42 bar Compatible with CHCs, CFCs, HFCs, CO2 and their oils and additives Optimised glass size for a clear view without hygroscopic effect Fixed construction protects against wear and soiling Monobloc construction for absolute tightness Two flared connections for easy installation Brass base body for corrosion resistance Various connection types possible: screw connection, solder connection Sales-promoting information: The VCYL 12 sight glasses offer you reliable monitoring and control of your refrigerant in refrigeration and air conditioning systems. Thanks to its clear view, robust design and versatile connection options, this product enables efficient maintenance and diagnosis of your systems. With the VCYL 12, you can be sure that your refrigerant circuit is always working optimally and that you can recognise and rectify potential problems at an early stage.
  • Available
  • Delivery Time : 2-5 business days
Regular price: €34.45
Sight glass Carly VCYL 33 MMS Solder connection 10 mm
Sight glass Carly VCYL 33 MMS Solder connection 10 mm
Sight glass Carly VCYL 33 MMS solder connection 10 mm Functional features: - Maximum operating pressure: 42 bar - Compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives - The glass size enables excellent visibility without the need for a that a central, hygroscopic bead impairs this. impaired. - The mounting design of the humidity indicator is such that it is designed so that it is not subject to wear, contamination oils and no residues in the refrigerant circuit. residues in the refrigerant circuit. It prevents turbulence, which which could have an unfavourable effect on the visibility of the refrigerant and does not cause a drop in pressure. - The monobloc design and the perfectly fitted viewing window window guarantee absolute tightness. - The low weight of the VCYL sight glasses means that no special fastening is required. - The base body of the sight glasses is made of brass and thus guarantees complete complete corrosion resistance. - The long copper soldering ends of the sight glasses allow the connections to be soldering of the connections. The solid construction of the base body/sight glass unit unit does not require disassembly of the glass. - Several types of connections are possible on the standard products: - Screw connection type SAE, Male/Male and Male/Female - For soldering on tubes in millimetres (MMS), female/female and male/female Application: - For quick and direct control of the flow rate, condition and moisture and moisture content of the refrigerant in liquid or two-phase two-phase state in refrigeration and air conditioning systems. Further information can be found in the data sheet above.
  • Available
  • Delivery Time : 1-3 business days
Regular price: €38.02
Discount Tip
Sight glass Carly VCYL 22 with 1/4" flare connection
Sight glass Carly VCYL 22 with 1/4" flare connection
Sight glass Carly VCYL 22 with 1/4" flare connection - Product description The Carly VCYL 22 sight glass with 1/4" flare connection is an excellent instrument for quickly and directly checking the flow, condition and moisture content of the refrigerant in refrigeration and air conditioning systems. It provides a clear view of the refrigerant and guarantees reliable performance.Technical details: Maximum operating pressure: 42 bar Compatibility with CHCs, CFCs, HFCs, CO2 and their oils and additives Glass size enables excellent visibility without impairment Fixed construction prevents wear and pressure drop Monoblock construction for absolute tightness Two flare connections for easy installation Complete corrosion resistance due to brass base body Advantages and benefits: This sight glass offers clear advantages for anyone who needs precise control of the refrigerant: Quick and direct check of flow and condition Provides clear visibility without interference Various connection options for easy installation
  • Available
  • Delivery Time : 1-3 business days
Sale price: €19.96 Regular price: €33.26 ( - 39.99% )
Sight glass Carly VCYL 34 MMS solder connection 12 mm
Sight glass Carly VCYL 34 MMS solder connection 12 mm
Sight glass Carly VCYL 34 MMS solder connection 12 mm Functional features: - Maximum operating pressure: 42 bar - Compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives - The glass size enables excellent visibility without the need for a that a central, hygroscopic bead impairs this. impaired. - The mounting design of the humidity indicator is such that it is designed so that it is not subject to wear, contamination oils and no residues in the refrigerant circuit. residues in the refrigerant circuit. It prevents turbulence, which which could have an unfavourable effect on the visibility of the refrigerant and does not cause a drop in pressure. - The monobloc design and the perfectly fitted viewing window window guarantee absolute tightness. - The low weight of the VCYL sight glasses means that no special fastening is required. - The base body of the sight glasses is made of brass and thus guarantees complete complete corrosion resistance. - The long copper soldering ends of the sight glasses allow the connections to be soldering of the connections. The solid construction of the base body/sight glass unit unit does not require disassembly of the glass. - Several types of connections are possible on the standard products: - Screw connection type SAE, Male/Male and Male/Female - For soldering on tubes in millimetres (MMS), female/female and male/female Application: - For quick and direct control of the flow, condition and moisture and moisture content of the refrigerant in liquid or two-phase two-phase state in refrigeration and air conditioning systems. Further information can be found in the data sheet above.
  • Available
  • Delivery Time : 1-3 business days
Regular price: €43.97
Sight glass Carly VCYL 36 MMS Solder connection 18 mm
Sight glass Carly VCYL 36 MMS Solder connection 18 mm
Sight glass Carly VCYL 36 MMS Solder connection 18 mmFunctional features: - Maximum operating pressure: 42 bar - Compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives - The glass size allows excellent visibility without a central hygroscopic bead impairing this.- The mounting design of the humidity indicator is such that it is not subject to wear, contamination by oils or residual substances in the refrigerant circuit. It prevents turbulence that could have an unfavourable effect on the good visibility of the refrigerant and does not cause a drop in pressure. - The monobloc design and the perfectly fitted inspection window guarantee absolute tightness. - The two flare connections are provided with a hexagonal spanner flat for easy installation and screwing in. - The male / female sight glasses for flanging are supplied with a centring copper gasket on the female side (except VCYL 25, where a non-centring copper gasket is included), which enables quick and secure positioning. - The male / female sight glasses can be screwed directly onto the outlet side of a filter drier. - Due to the low weight of the VCYL sight glasses, no special fastening is required. - The base body of the sight glasses is made of brass, guaranteeing complete corrosion resistance. - Several types of connections are possible on the standard products: - Screw connection type SAE, Male/Male and Male/Female - For soldering on tubes in millimetre (MMS), Female/Female and Male/Female Application: - For quick and direct control of flow, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems. For more information, see the data sheet above.
  • Available
  • Delivery Time : 2-5 business days
Regular price: €71.28