Skip to main content Skip to search Skip to main navigation
Menu

Sight glass Carly VCYLS 7 for soldering to 7/8" pipes

37-VCYLS7
Contact
Privacy
Fields marked with asterisks (*) are required.
Description
Carly VCYLS 7 sight glass for soldering to 7/8"

Functional features:
- The products are compatible with CHCs, CFCs, HFCs, CO2, as well as their oils and associated additives. They are designed for use with non-hazardous refrigerants of group 2 of PED 2014/68/EU. For the use of CARLY components with Group 1 fluids of the hydrocarbon type - propane R290, butane R600, isobutane R600a, propylene R1270 - with HFCs and transcritical CO2 and for an application of organic cycle of RANKINE, please contact CARLY technical service.
- The classification of products according to their nominal size in EC categories is shown in the table of PED 2014/68/EU.
- Monitoring of the refrigerant condition in the liquid line by means of a large inspection window. The possible presence of bubbles in the refrigerant is visualised by the VCYL and, in addition to a lack of refrigerant, can have various causes such as too low or no subcooling, high pressure loss through the filter drier, which in this case must be replaced immediately.
- A reliable hygroscopic indicator that reacts to moisture and is resistant to acid is positioned under the sight glass.
- Moisture is indicated by a colour change of the indicator (green = refrigerant dry, yellow = refrigerant too moist) The continuous indication is tried and tested, as is the reversible colour change. It is very important to check the moisture content of the refrigerant in order to avoid the formation of acid, which is detrimental to the proper functioning of the system.
- The sight glass consists of three parts:
- a brass plate, which is soldered directly onto the pipework after it has been drilled.
- a sight glass with moisture indicator, which is screwed onto the plate.
- an O-ring seal made of PTFE, which ensures tightness between the plate and sight glass.

Application:
- For quick and direct monitoring of the flow rate, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems.

For more information, see the data sheet above.
Downloads

Data and Illustrations without Guarantee

Manufacturer "Carly"

CARLY

CARLY is a French manufacturer of components for refrigeration and air conditioning systems, headquartered in Lissieu, France. Since its foundation in 1923, the company has specialised in the development and production of solutions for refrigeration and air conditioning technology. CARLY operates internationally and offers a wide range of products for various applications in refrigeration and air conditioning technology.

Product groups and specialisations:

CARLY offers a comprehensive range of products for refrigeration and air conditioning technology:

  • Filtration, drying and decontamination: products for the filtration and drying of refrigerants, as well as for the decontamination of systems.
  • Service products: Maintenance products such as cleaning and disinfecting agents for refrigeration and air-conditioning systems.
  • Refrigeration fittings: Connectors for refrigerant circuits.
  • Noise and vibration damping: Products for reducing noise and vibrations in systems.
  • Tanks, liquid separators and coil condensers: Components for the storage and transport of refrigerants.
  • Refrigeration valves: Valves for regulating the flow of refrigerant.
  • Oil control systems: Systems for monitoring and managing oil flow in refrigeration systems.

This wide range of products underscores CARLY’s commitment to quality and innovation in refrigeration and air conditioning technology.

 

Manufacturer details (information requirements under the GPSR Product Safety Regulation):

Manufacturer: CARLY GmbH

Postal address: Steigerstraße 5 67811 Dielkirchen Germany

Email address: [email protected]

Website: www.carly-sa.de

Properties
Connection: Connection
Connection size: 7/8"
Item condition: New item

Data and Illustrations without Guarantee

Downloads

Do you have some questions about this product?

Skip product gallery

Artikel Zubehör

Sight glass Carly VCYLS 9 for soldering to 1 1/8" pipes
Sight glass Carly VCYLS 9 for soldering to 1 1/8" pipes
Sight glass Carly VCYLS 9 for soldering to 1 1/8"Functional features:- The products are compatible with CHCs, CFCs, HFCs, CO2, as well as their oils and associated additives. They are designed for use with non-hazardous refrigerants of group 2 of PED 2014/68/EU. For the use of CARLY components with Group 1 fluids of the hydrocarbon type - propane R290, butane R600, isobutane R600a, propylene R1270 - with HFCs and transcritical CO2 and for an application of organic cycle of RANKINE, please contact CARLY technical service. - The classification of products according to their nominal size in EC categories is shown in the table of PED 2014/68/EU. - Monitoring of the refrigerant condition in the liquid line by means of a large inspection window. The possible presence of bubbles in the refrigerant is visualised by the VCYL and, in addition to a lack of refrigerant, can have various causes such as too low or no subcooling, high pressure loss through the filter drier, which in this case must be replaced immediately. - A reliable hygroscopic indicator that reacts to moisture and is resistant to acid is positioned under the sight glass. - Moisture is indicated by a colour change of the indicator (green = refrigerant dry, yellow = refrigerant too moist) The continuous indication is tried and tested, as is the reversible colour change. It is very important to check the moisture content of the refrigerant in order to avoid the formation of acid, which is harmful to the proper functioning of the system. - The sight glass consists of three parts: - a brass plate, which is soldered directly onto the pipework after it has been drilled. - a sight glass with moisture indicator, which is screwed onto the plate.- an O-ring seal made of PTFE, which ensures tightness between the plate and sight glass.Application: - For quick and direct monitoring of the flow rate, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems.For more information, see the data sheet above.
  • Available
  • Delivery Time : currently not available - please ask for delivery time
Regular price: €53.43
Sight glass Carly VCYL 34 MMS solder connection 12 mm
Sight glass Carly VCYL 34 MMS solder connection 12 mm
Sight glass Carly VCYL 34 MMS solder connection 12 mm Functional features: - Maximum operating pressure: 42 bar - Compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives - The glass size enables excellent visibility without the need for a that a central, hygroscopic bead impairs this. impaired. - The mounting design of the humidity indicator is such that it is designed so that it is not subject to wear, contamination oils and no residues in the refrigerant circuit. residues in the refrigerant circuit. It prevents turbulence, which which could have an unfavourable effect on the visibility of the refrigerant and does not cause a drop in pressure. - The monobloc design and the perfectly fitted viewing window window guarantee absolute tightness. - The low weight of the VCYL sight glasses means that no special fastening is required. - The base body of the sight glasses is made of brass and thus guarantees complete complete corrosion resistance. - The long copper soldering ends of the sight glasses allow the connections to be soldering of the connections. The solid construction of the base body/sight glass unit unit does not require disassembly of the glass. - Several types of connections are possible on the standard products: - Screw connection type SAE, Male/Male and Male/Female - For soldering on tubes in millimetres (MMS), female/female and male/female Application: - For quick and direct control of the flow, condition and moisture and moisture content of the refrigerant in liquid or two-phase two-phase state in refrigeration and air conditioning systems. Further information can be found in the data sheet above.
  • Available
  • Delivery Time : 1-3 business days
Regular price: €43.97
Sight glass Carly VCYLS 5 for soldering to 5/8" pipes
Sight glass Carly VCYLS 5 for soldering to 5/8" pipes
Sight glass Carly VCYLS 5 for soldering to 5/8"Functional features:- The products are compatible with CHCs, CFCs, HFCs, CO2, as well as with their oils and associated additives. They are designed for use with non-hazardous refrigerants of group 2 of PED 2014/68/EU. For the use of CARLY components with Group 1 fluids of the hydrocarbon type - propane R290, butane R600, isobutane R600a, propylene R1270 - with HFCs and transcritical CO2 and for an application of organic cycle of RANKINE, please contact CARLY technical service. - The classification of products according to their nominal size in EC categories is shown in the table of PED 2014/68/EU. - Monitoring of the refrigerant condition in the liquid line by means of a large inspection window. The possible presence of bubbles in the refrigerant is visualised by the VCYL and, in addition to a lack of refrigerant, can have various causes such as too low or no subcooling, high pressure loss through the filter drier, which in this case must be replaced immediately. - A reliable hygroscopic indicator that reacts to moisture and is resistant to acid is positioned under the sight glass. - Moisture is indicated by a colour change of the indicator (green = refrigerant dry, yellow = refrigerant too moist) The continuous indication is tried and tested, as is the reversible colour change. It is very important to check the moisture content of the refrigerant in order to avoid the formation of acid, which is detrimental to the proper functioning of the system. - The sight glass consists of three parts: - a brass plate, which is soldered directly onto the pipework after it has been drilled. - a sight glass with moisture indicator, which is screwed onto the plate.- an O-ring seal made of PTFE, which ensures tightness between the plate and sight glass.Application: - For quick and direct monitoring of the flow rate, condition and moisture content of the refrigerant in liquid or two-phase state in refrigeration and air conditioning systems.For more information, see the data sheet above.
  • Available
  • Delivery Time : 2-5 business days
Regular price: €53.43
Shop Assistant AI

You are chatting with an AI assistant. Replies may contain errors and are non-binding.

Hello, I am your shop assistant, how may I help you?