- Cold
-
Climate
- Portable air conditioners
- Tools air conditioning
- Air conditioners
- Accessories air conditioners
- Spare parts for air conditioners
- Consoles
- Insulated copper pipes
- Drain pipes
- Roof duct
- Refrigerant distributor
- Refrigerant lines flex.
- Condensate pumps
- Condensate trays
- Mounting channels
- Oil protection systems
- Ventilation
- Heat pumps
- Tools
- Promotional merchandise
- B2B Suite
- Enquiry form
- Manufacturer
Condensate pumps
Which condensate pump do I need?
Choose the application; the finder calculates quantity and lift height using manufacturer data.
- Wall-mounted unit (split)Mini pump in the unit, in the trunking or underneath
- Cassette & ceiling unitTank pump, ideally with alarm contact
- Floor consoleMini pump in the unit or tank pump
- Ducted unitTank pump for larger quantities
- Refrigerated cabinets & cold roomsPumps for defrost water
Compare best sellers
| Pump | Type | Max. flow rate | Max. lift height | Noise | Alarm contact | Price (1 pc) | Order |
|---|---|---|---|---|---|---|---|
| VAMP-FRefco | In the unit | 22 l/h | 15 m | 20 dB(A) | yes | €141.15 | |
| COMBIRefco | In the unit | 42 l/h | 20 m | 20 dB(A) | yes | €149.71 | |
| VAMP-XRefco | In the unit | 22 l/h | 15 m | 20 dB(A) | yes | €147.07 | |
| Silent+ Mini Orange FP3430 (5. Generation)Aspen | In the unit | 35 l/h | 10 m | 16 dB(A) | yes | €175.39 | |
| Mini Tank FP1056/2Aspen | Tank pump | 35 l/h | 15 m | 35 dB(A) | yes | €156.19 | |
| Secura-Split XS 5000-STD 15 L/hDelco Controls AG | In the unit | 15 l/h | 12 m | 19 dB(A) | yes | €129.71 | |
| Si-30Sauermann | In the unit | 20 l/h | 10 m | 20 dB(A) | yes | €173.17 | |
| Silent+ Mini Lime FP3322/5 (Ersatzpumpe ohne Kanal)Aspen | Trunking pump | 40 l/h | 15 m | 16 dB(A) | yes | €173.17 | |
| Silent+ Mini Aqua FP3420 (5. Generation)Aspen | In the unit | 35 l/h | 10 m | 16 dB(A) | yes | €203.48 | |
| Mini Aqua FP2406/2Aspen | In the unit | 12 l/h | 10 m | 21 dB(A) | yes | €156.19 |
Manufacturer data (as of 20.10.2026). Flow rate at 0 m lift height. Volume pricing from 5 and 10 pcs on the product page. Preise inkl. MwSt.
Filter products
More filters (2) Fewer filters
Do you have some questions about this products?
- Your personal contact person
- Ergün Polat
- [email protected]
- +49 2554 912 983 9
-
🙋 Ergün Polat
Not found what you are looking for?
You need Individual Solutions or larger Quantities?
- Voltage
- 230V
- Delivery volume
- 5 l/h
Ready to ship in approx. 6 business days
- Voltage
- 100-240V
- Delivery volume
- 40 l/h
Ready to ship in approx. 6 business days
Charles Austen
Charles Austen defrost water pump MEGABLUE X87-814 with sensor - L = 2M - 64X276X51MM- Voltage
- 230V
- Cable length
- 2 m
Ready to ship in approx. 6 business days
Aspen Pumps
Condensate pump tank pump ASPEN - ERRP - with side inlet, 225 l/h, (FP2318)- Voltage
- 230V AC
- Flow rate
- 225 l/h
- Protection class
- IPX4
Available
Charles Austen
Charles Austen T18-016 Blue Diamond air conditioning sub-assembly kit MicroBlue FasciaAvailable
Sauermann
Sauermann condensate pump DeltaPack RAL9001 duct 80X60mm (20/LH)22dBA cream white- Voltage
- 230V
- Flow rate
- 20 l/h
Available
Ready to ship in approx. 6 business days
We determine the availability shown in this list from current stock and restocking times, regardless of the delivery country. We calculate the estimated delivery date for your delivery country on the product page and in the cart.
Can't find what you are looking for?
Send us a photo of the nameplate. We will check the successor type and availability.
Request a replacement →Frequently asked questions about condensate pumps
When do I need a condensate pump?
Whenever the condensate cannot run to the drain by gravity. Typical cases: the indoor unit is mounted on an interior wall, the drain is higher than the unit, or a cassette sits in a suspended ceiling with no drain nearby.
How much condensate is produced?
As a rule of thumb, in humid air you can expect 0.5 to 0.8 litres per hour per kW of cooling capacity. A 3.5 kW unit therefore produces up to around 2.8 litres per hour.
Why is the lift height so important?
The flow rate in the data sheet applies to a height of 0 m. With every metre the pump delivers less. An example from a manufacturer's data sheet: 20 litres per hour at 0 m, but only 4 litres per hour at 10 m. The maximum lift height is therefore not a working height.
How loud is a condensate pump?
According to the manufacturers, current mini pumps are at around 16 to 23 dB(A). Check the measuring distance in the data sheet. In bedrooms, a pump in the trunking or outside the room is often the better choice.
Do I need an alarm contact?
Wherever overflowing water causes damage, i.e. with ceiling and cassette units, above electronics or in server rooms. In the event of a fault, the contact switches the air conditioner off or reports the fault before the tank overflows. The connection is made by a qualified installer.
Mini pump, trunking pump or tank pump?
Mini pumps sit with their sensor in or directly on the indoor unit. Trunking pumps disappear into the trunking next to the unit. Tank pumps collect the water in a tank with a float and suit cassettes, floor consoles, ducted units and larger quantities.
Is an air conditioning condensate pump suitable for a condensing boiler?
Only if the manufacturer explicitly approves it for this. Condensate from condensing boilers is acidic, and not every pump can cope with that. Whether neutralisation is also needed depends on output, fuel and local requirements.
My old pump is no longer available. What now?
In the finder, enter the type or item number under “Replacement for an old pump”. We show the successor or an equivalent pump. Before swapping, check dimensions, sensor and connections against the data sheet.
How do I keep the pump clean?
Slime and dirt from the condensate tray are the most common cause of faults. Clean the tray and pump during the annual service and, if needed, use tablets against bacterial growth in the condensate tray.